APPendix

APPendix A:Safety precautions

1 before using the instrument, please check whether the power supply is normal, to ensure the normal use of the instrument and personal safety

2 Be sure to use it within the scope of the technical indicators of the instrument.

3 please do not arbitrarily change the instrument circuit, so as not to damage the instrument and endanger safety.

APPendix B:Warning and personal injury

Do not use the product on safety protection devices or emergency stop equipment, or in any other application where the failure of the product may cause personal injury, unless there is a special purpose or authorization to use the product. Refer to the technical indicators in the instructions before installation and use. Failure to follow this advice may result in death or serious injury. The Company will not be liable for any compensation for personal injury or death arising therefrom, and will be exempted from any claims that may be made against the company’s managers and employees, affiliated agents, distributors, etc., including various costs, compensation costs, attorney’s fees, etc.

APPendix C:

standard: describe quantity
host USB host signal generator 1
choosable: describe quantity
accessory SMA to alligator clamp line 1

APPendix D:Summary of the warranty

Zhengzhou Feiyi Technology Co., Ltd. promises that the instrument host and accessories produced by the company will be free from any material and process defects during the warranty period. During the warranty period, if the product is proved to be defective, FeelElec will repair or replace the product free of charge. The warranty period of the instrument is 1 year from the date of delivery. Damage caused by improper operation or maintenance, unauthorized modification of the instrument or irresistible natural disasters is not covered by the warranty.

APPendix E:Communication program description

String Communication Protocol Description

Communication data Fuction Data specification
“fxxx” Control Frequency Set the frequency to XXX, for example, F1000, set the frequency to 1K
“w1” Control waveform The control waveform is sine wave
“w2” Control waveform The control waveform is triangle wave
“w3” Control waveform The control waveform is square wave
“s1” save settings Save the frequency and waveform data to the lower computer. By default, the saved frequency and waveform data are used for power-on
“c” Communication switch Switch the communication protocol to Modbus

modbus Communication Protocol Description

Address Order Register address Register length CRC check codes function declaration
0x01 0x03 0x0000 0x0002 xxxx Read frequency data
0x01 0x03 0x0002 0x0001 xxxx Reading waveform data
Address Order Register address Register value CRC check codes function declaration
0x01 0x06 0x02 0x01 xxxx Output sine wave
0x01 0x06 0x02 0x02 xxxx Output triangle wave
0x01 0x06 0x02 0x03 xxxx Output square wave
0x01 0x06 0x03 0x01 xxxx Save set
0x01 0x06 0x04 0x01 xxxx Cut Communication
Address Order Register address Register length number of bytes Register value function declaration
0x01 0x10 0x00 0x02 0x04 xxxxxxxx The control frequency is the register value

Note: Communication data refers to the data sent by the upper computer to the lower computer through the serial port.